ALPHANUMERIC 10000 Divisions
Class III Maximum Certification:
10000 divisions
1µV step
40? load (16 load cells of 700?)
4 x 20 characters alphanumerical display.
Text edition through PC keyboard.
Embedded power supply.
Clock/Calendar as standard.
Until 1000 weighing registers memory.
Listing and tickets from memory.
Double RS232 output: connection to PC and printer
Versions
· SC 20/A: Analogic indicator
· SC 20/D: Digital load cells indicator
· SC 20/BAT12: For external battery 12 V indicator
· SC 20/BB: Bibáscula / Bibascule
Basic configuration
· Truck-weighing
· Pieces Counter
· Axles-weighing
· Multirange
· Communications 2 RS-232 ports
· Compatible protocols
· Hardware
– Clock-Calendar
– Connector for PC keyboard (PS/2)
· Languages Spanish, English, French, Italian & Portuguese
Standard software
– Piececounter
– Piece-Tare-Codes
– Truck weighing
– Axes weighing
Optional hardware
– External 12V battery.
– 2 Optocoupled inputs and 6 relay outputs
– Converts 1st or 2nd RS232 optocoupled channel to RS485.
– Converts 1st or 2nd RS232 channel to RF
– Bibascule
– DSD feature (until 4000 weighings)
Optional
– Customized software
– Semaphore
– Multirange
Available printers
· LX-300 from EPSON
· SRP 275 from SAMSUNG
· SP298 from STAR
· TM295 from EPSON
Technical data
Accuracy class III
Maximum number of verification scale intervals 10000
Load cell excitation power supply 8 V DC
Max. signal voltage for dead load 16 mV
Minimum signal voltage for dead load 0 mV
Minimum input voltage per verification scale interval 1µV
Measuring range minimum voltage 8 mV
Measuring range maximum voltage 24 mV
Minimum load cell impedance 40 ?
Maximum load cell impedance 2000 ?
Minimum temperature range -10º C
Maximum temperature range 40º C
Power supply requirements (options SC20/A or SC20/D) 220 V AC
Power supply requirements (option SC20/BAT12) 12 V DC
Sense system Available
Load cell cable length
4 wire systems 5 m/mm2
6 wire systems No limit